This professional, waterproof meter complies with IP67 standards and measures DO, barometric pressure, and temperature.
The HI-98198 is supplied with a HI-764113 digital optical dissolved oxygen probe in a custom thermoformed durable carrying case with accessories. It is compact and ergonomically designed to provide ready access to the materials required for routine sampling.
The meter is supplied with:
HI-764113 Optical DO probe with built-in temperature sensor, protective shield and 4m (13’4) cable
HI-764113-1 Smart Cap™ with o-ring
HI-7040 Bicomponent Zero Oxygen Solution
Calibration/Storage vessel
100ml plastic beaker (2 pcs)
1 syringe with silicon grease
1 lens wipe
1.5V AA batteries (4 pk)
Instruction manual
Meter quality certificate
Probe quality certificate
Cap quality certificate
USB Type A to C cable
Carry case
Other features include:
Text messages on the graphic LCD display to warn and guide the user
Back lighted display
One or two points calibration at 0 or/and 100% saturation (with auto recognition)
A single point manual calibration in mg/L or % saturation using a reference method for calibration value
A dedicated HELP key for assistance anytime
A user selectable “calibration due” warning
A dedicated GLP key that includes the last 5 calibrations with time, date, calibration points, as well as barometric pressure, temperature and salinity setting
AutoEnd freezes the next stable measurement value on the display
Log on demand with 4000 records capability
USB-C port for easy data transfer to memory stick, PC or other compatible devices
The HI-98198 opdo™ is only compatible with the Hanna digital dissolved oxygen probe HI-764113.
Concentration measurements are automatically compensated for barometric pressure, temperature and salinity. Barometric pressure and temperature are automatically measured and compensated. Salinity is automatically compensated by setting manually the salinity concentration of the water being measured. The meter also has a built in application to measure and calculate BOD (biological Oxygen Demand), OUR (oxygen uptake rate), and SOUR (Specific Oxygen Update Rate).
How the probe works
The Hanna HI-764113 optical DO sensing probe is based on the principle of fluorescence quenching. The sensing method features an immobilised pT based luminophore that is excited by the light of a blue LED and emits a red light. Dissolved oxygen quenches this excitation.
The major components of the probe include a blue LED for excitation, a red LED that is used as a reference light, and a photodetector. The Smart Cap™ is locked in place on the optical probe and includes the immobilised 0sub2/sub sensitive luminophore with rugged insoluble black oxygen permeable protective layer.
The sensor provides accurate DO measurements over long periods of time without the need for frequent calibration.
Dissolved Oxygen
Range
0.00 to 50.00 mg/L/0.0 to 500.0% saturation
Resolution
0.01 mg/L/0.1% saturation
Accuracy
1% of reading ±0.01 mg/L for 0.00-20.00mg/L;5% of reading for 20.00-50.00mg/L;1% of reading ±0.1% for 00-200.0%;5% of reading for 200.0-500.05
Barometric Pressure
Range
420 to 850 mmHg
Resolution
1 mmHg
Accuracy
±3 mmHg within ±15% from the calibration point
Temperature
Range
-5.0 to 50.0°C
Resolution
0.1°C
Accuracy
±0.3°C
DO Calibration
One of two points automatic calibration at 100% (8.26 mg/L and 0% (0mg/L)
Single point manual using a value entered by the user in % saturation or mg/L
Temperature Calibration
Single point anywhere within temperature range
Pressure calibration
Single point anywhere within pressure range
Temperature Compensation
Automatic from -5.0 to 50.0°C
Pressure Compensation
Automatic from 420 to 850 mmHg
Salinity Compensation
Automatic from 0 to 70g/L (manually set)
DO Probe
HI-764113 Optical Probe
LOG
On demand with 4000 records capability
Battery type/life
1.5 v AA batteries (4 pk)/ approx. 200 hours of continuous use without backlight (50 hours with backlight)
Auto power off
User selectable: 5, 10, 30, 60 minutes or disabled
PC Connectivity
USB-C
Dimensions
185 x 93 x 35.2mm
Meter Weight with batteries
450g
Case Ingress Protection Rating
IP67
Environment
0 to 50°. RH 100%
/table
HI-764113 Probe Specification
Probe Body Material
ABS
Smart Cap™ material
Polypropylene
Cable jacket material
PVC
Cable Length
4m, 10m and 20m options
probe guard
316 Stainless steel
Temperature Measurement
Thermistor
Pressure
20m (29 PSI)
Probe Dimensions with guard
174 x 25mm
Response Time
45 seconds
Probe weight with guard
400g with 4m cable length
probe ingress protection rating
IP68
Sensor type
Optical; luminescence quenching
/table