The HI 991301 high range meter offers great precision at high range to meet exacting requirements for testing pH, electro-conductivity, total dissolved solids and temperature.
The HI-991301 high range meter offers great precision at high range to meet exacting requirements for testing pH, electro-conductivity, total dissolved solids and temperature.
Designed for optimum consistency and reproducibility the HI-991301 portable high range conductivity meter offers a great range of user selectable features to deliver greater consistency and reproducibility
Different TDS factors ranging from 0.45 to 1.00 Temperature coefficients (ß) ranging from 0.0 to 2.4%
Each meter is supplied complete with:
HI-12883 pH/EC/TDS probe with built-in temperature sensor, DIN connector and 1mm cable
pH 4.01 & 7.01 buffer sachets
HI-70030 12880 µS/cm and HI-70038 6.44 ppt calibration solution – 1 sachet of each
HI-700601 Electrode cleaning solution (2 sachets)
100ml beaker
Alkaline batteries: 1.5V AAA x 3
Rugged carrying case
Calibration certificate of meter
Calibration certificate of probe
Instruction manual
About the HI-12883 probe
The HI-12883 multi-parameter probe, incorporates a domed shaped pH bulb rated from 0-13 pH, a single junction Ag/Cl reference electrode with gelled electrolyte and a retractable cloth wick junction, a graphite EC/TDS cell, and a temperature sensor in one convenient, rugged polypropylene body. In addition, to ensure against interference from transient electrical noise to pH, a solid-state pre-amplifier is integrated into the probe. The probe is rated from 0 to 50°C.
Main features:
Simultaneous, pH, EC/TDS and temperature measurements on a large three line LCD display
Selectable temperature unit
pH electrode condition display
mV of pH measurement for electrode check
Last calibration points pH and EC
HI-12883 dedicated pH/EC/TDS/temperature probe
Probe quick connect system
Battery life indication and low battery detection
Auto-off function
Keystroke confirmation tone
Waterproof casing IP67
Replaceable Electrode – No need to replace the whole meter when the electrode needs replacing. Spare and replacement electrodes are available for this product.
PC Interface – Download test results to a computer programmed with HANNA’s Windows® compatible software (HI-92000), directly from equipment via a USB port or a RS232 cable outlet. (Also see Bluetooth Connection).
Optional shockproof silicon rubber boot
Specially designed to protect your instrument from damage or impact – HI-710028 – Orange, HI-710029 – blue. Buy separately.
pH Range
-2.00 to 16.00 pH*
pH-mV
±825 mV (pH-mV)
EC
0 .00 to 20.00 mS/cm**
TDS
0.00 to 10.00ppt (g/L)
Temperature Range
-5.0 to 105.0°C
pH Resolution
0.01 pH
pH-mV Resolution
1 mV
EC
1µS/cm
TDS
1ppm (mg/L)
Temperature Resolution
0.1°C
pH Accuracy @20°C
±0.02 pH
pH-mV
±1 mV
EC/TDS
±2%F.S.
Temperature Accuracy
±0.5°C
pH Electrode
HI-12883 pH/EC/TDS temperature sensor, Quick Connect DIN connector and 1 m (3.3′) cable (included); please note: HI-12883 is limited to be used from 0 to 13 pH and from 0 to 50°
TDS Conversion factor
Selectable from 0.45 to 1.00 with 0.01 increments
Battery Type / Life
3 x 1.5V AAA / approx. 600 hours of continuous use
Environment
0 to 50°C (32 to 122°F); RH max 100%
Dimensions
154 x 63 x 30 mm
Weight
196 g
Case Protection Rating
IP67
Ordering information
HI-991301 is supplied with HI-12883 pH/EC/TDS probe with built-in temperature sensor, DIN Connector and 1m cable, pH 4.01 and 7.01 buffer sachets, HI-70030 12880 µS/cm and HI-70038 6.44 ppt calibration solution sachets, HI-700601 electrode cleaning solution sachets (2), 100mL beaker, 1.5V AAA batteries (3), calibration certificate of meter, calibration certificate of probe, instruction manual and HI-710142 rugged carry case.
/table